Per Acetic Acid (PAA) Control System

Per Acetic Acid Controller

Description

Per Acetic Acid Control System
The Per Acetic Acid Control System is an advanced controller designed for high‐end applications. The units feature an independent
proportional control output, probe quality checking, and a variety of outputs. The user has full programming authority. Per Acetic Acid Control System is not dependent on pH within typical operating levels, and its value or efficacy does not vary with changes in pH. Therefore, a pH control system is not required to be used, unlike chlorine treatment for effective treatment.
Parameters of Per Acetic Acid Control System:
  • PH / ORP
  •  Conductivity
  • Flow Rate
  • Chlorine
  • Per Acetic Acid
  • Hydrogen Peroxide
  • Custom Measure for 4÷20mA input
Applications of Per Acetic Acid Control System.
  • Waste Water
  • Drinking-Water
  • Pure Water
  • Cooling Towers
  • Boiler
  • Reverse Osmosis
  • Crate Wash
  • Galvanic Process
  • CIP
  • Irrigation
  • Swimming Pool
  • Dairy

    Features of Per Acetic Acid Control System:

  • Graphic display 128 by 128-pixel resolution monochrome high brilliance display with white backlight.
  • Graphic icons to show digital output status, washing cycle, alarms menu.
  • Simultaneous flashing values for the measurement and temperature readings.
  • The toolbar menu allows a series of views for the various menus, for programming, and for viewing during operation.
  • Outputs Status bar to visualize information in real-time.
  • The index menu allows user-friendly navigation.
  • Reverse function for invert the writings to obtain a high contrast.
Keypad
  • Five (5) control keys for instrument calibration and configuration.
  • Enclosure Box
  • Wall mounting
  • ABS plastic material IP65 full box (144×144).
  • Panel mounting
  • ABS IP65 front panel only (96x96x42). Kontrol 50
    Kontrol SEKO Per Acetic Acid Controller in Pakistan. SEKO Pakistan

    Measure range:

  • pH 0 ÷14,00 pH
  • ORP ± 2000 mV
  • Conductivity 0,054÷20 /200 /2.000 /20.000 /200.000 μS(*)
  • Temperature with PT100/PT1000 0÷100°C (32÷212 °F)
  • Code Description
  • Product line
  • K50PR for pH or ORP values
    Code
  • Kontrol PR 50
  • K50CD Kontrol CD 50 for Conductivity values
  • K50FX Kontrol FX 50 for Flow Rate value code Description
    Kontrol 50 Single parameter
    Flow Rate 0 ÷ 99.999 Liters/Sec. (**)
    Toolbar menu The user‐friendly programming step
    Menu by Toolbar functions.
    Outputs Status bar Quick information thanks to
    The status bar in real-time.
    Index menu The user‐ friendly navigation thanks to
    index menu.
    Alarms menu The user‐ friendly menu for feedback
    alarm log.
    K50CL Kontrol CL 50 for Chlorine values
    Chlorine and Chlo. Dioxide 0÷0,50/1,00 /2,00 /5,00 /10,0 /20,0 /200,0 ppm
Power Supply
Universal Power Supply
100÷240 Vac 50/60 Hz.
Low Power Supply
12÷32Vdc or 24 Vac.
CE compliant.
Configuration Outputs All outputs Relay, SSR, and Output mA are configurable with primary and secondary measures.
Current outputs
4÷20mA Galvanic isolation
One (1) independent programmable Output Measures with Proportional routine regulation.
Relay Outputs
Two (2) independent relays, two (2) setpoints, alarm remote, and backwashing probe setting by software.
On/OFF, Timed routine function setting.
Solid State Relay (SSR)
One (1) Frequency output signal, two (2) setpoints with Proportional routine regulation.
Per Acetic Acid Control System/PAA Control Panel
Disinfectant Control System for Recirculating Water – Dilution Solutions PAA Control Panel is a simplified configuration, for maintaining Recirculating Water in Sanitizing and Disinfecting applications. Designed to minimize the potential for spread of pathogens, such as E. coli and Listeria, in vegetable and fruit washing recirculating water systems.
  • Automated – no manual operation of pumps
  • Automated – no titration required to maintain disinfectant
  • Automated – no handling of dangerous chemicals
  • Electric pump with integrated controller
  • PAA electrode continuously monitors concentration to maintain desire set point
  • The proximity switch puts the system into standby mode when sample flow is interrupted
  • Alarm functionality (Hi / Lo) concentrations built into the pump
  • Pump protected – Auto shut off when the chemical container is empty
  • Flush valves on clear strainers, for maintaining clean sample water supply for analysis, to protect and prevent the electrode from fouling
  • Easy maintenance!!
  • Economical cost!!